{"product_id":"cats-tonometer-prism","title":"CATS Tonometer Prism - CATS®-D Disposable","description":"\u003ch5\u003e\n\u003cspan style=\"text-decoration: underline; color: #ff0000;\"\u003eCATS-R SKU 10511\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003e- CATS® Reusable Tonometer Prism for Goldmann\/Perkins Tonometers - The New Shape of IOP\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cp\u003eCATS® Tonometer Prism is designed to deliver improved accuracy in Goldmann IOP measurements for all patients. The CATS® Prism seamlessly integrates with all Goldmann and Perkins tonometers, and its ergonom\u003cspan style=\"color: #000000;\"\u003eic design enables confident, comfor\u003c\/span\u003etable use with no change to the clinician’s measurement technique. Simply exchange the prism to modernize your Goldmann tonometer measurement.\u003cbr\u003eSaving and preserving sight is the goal of every eye care practitioner. Unfortunately, IOP measurement is compromised due to \u003cstrong\u003eerrors\u003c\/strong\u003e caused by corneal biomechanics for 50% of patients. Traditional Goldmann prisms “flatten” the cornea, which amplifies intracorneal stress during the measurement process and distorts the IOP results.\u003cbr\u003eThe CATS® Prism’s dual-curved surface reduces measurement errors caused by corneal thickness, corneal hysteresis, curvature, and tear film. This curvature-matching principle of the CATS® Prism, “cups” the cornea, reducing the impact of corneal thickness and corneal biomechanics on the IOP measurement. Additionally, the rolled outer edge minimizes tear film adhesion that plagues traditional Goldmann prisms.  Made in the USA.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e• Designed for improved IOP measurement accuracy\u003cbr\u003e• Ergonomic design enables confident, comfortable use in the clinic\u003cbr\u003e• Integrates seamlessly with all Goldmann and Perkins type tonometers by simply exchanging the prism\u003cbr\u003e• No change to the clinician measurement technique\u003cbr\u003e• Multiple scientific peer-reviewed studies validate performance\u003cbr\u003e• Made in the USA\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e• SKU 10511 package dimensions: 5.75″ (W) x 2.25″ (D) x 0.625″ (H)\u003cbr\u003e• SKU 10511 Weight: .08 lbs\u003cbr\u003e• Country of Origin: USA\u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan style=\"text-decoration: underline; color: #ff0000;\"\u003eCATS-D SKU 10512\u003c\/span\u003e\u003cbr\u003e- CATS® Disposable, Sterile Tonometer Prism for Goldmann\/Perkins Tonometers – 100\/Box - The New Shape of IOP\u003c\/h5\u003e\n\u003cp\u003eCATS® Tonometer Prism is designed to deliver accurate Goldmann IOP measurements for all patients. For sterility and protection, the disposable CATS® Prism has a new Snap-Fit™ feature enabling true one-hand installation and disposal of the prism tip.\u003c\/p\u003e\n\u003cp\u003eThe CATS® Prism seamlessly integrates with all Goldmann and Perkins tonometers, and its ergonomic design enables confident, comfortable use with no change to the clinician’s measurement technique Simply exchange the prism to modernize your Goldmann tonometer measurement.\u003cbr\u003eSaving and preserving sight is the goal of every eye care practitioner. Unfortunately, IOP measurement is compromised due to errors caused by corneal biomechanics for 50% of patients. Traditional Goldmann prisms “flatten” the cornea, which amplifies intracorneal stress during the measurement process and distorts the IOP results.\u003c\/p\u003e\n\u003cp\u003eThe CATS® Prism’s dual-curved surface reduces measurement errors caused by corneal thickness, corneal hysteresis, curvature, and tear film. This curvature-matching principle of the CATS® Prism, “cups” the cornea, reducing the impact of corneal thickness and corneal biomechanics on the IOP measurement. Additionally, the rolled outer edge minimizes tear film adhesion that plagues traditional Goldmann prisms.  Made in the USA. 100\/Box\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e• The Snap-Fit™ feature allows for true one-handed installation and disposal of the prism tip\u003cbr\u003e• Preserves sterility and clinician protection\u003cbr\u003e• Designed for improved IOP measurement accuracy\u003cbr\u003e• Ergonomic design enables confident, comfortable use in the clinic\u003cbr\u003e• Integrates seamlessly with all Goldmann and Perkins type tonometers by simply exchanging the prism\u003cbr\u003e• No change to the clinician measurement technique\u003cbr\u003e• Multiple scientific peer-reviewed studies validate performance\u003cbr\u003e• Made in the USA\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e• SKU 10512 package dimensions: 9.25″ (W) x 7.25″ (D) x 3.25″ (H)\u003cbr\u003e• SKU 10512 Weight: .75 lbs\u003cbr\u003e• Country of Origin: USA\u003c\/p\u003e\n\u003cp\u003e\u003c!--more--\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- wp:paragraph --\u003e\u003c\/p\u003e\n\u003cp\u003eDownload:\u003cbr\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/stateless-precision-vision\/2023\/11\/be175ce5-cats-whitepaper-09.2023.pdf\"\u003eWhite Paper\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/stateless-precision-vision\/2023\/11\/cd170d2e-cats-technical-qa-09.2023.pdf\"\u003eTechnical Q \u0026amp; A\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- \/wp:paragraph --\u003e\u003c\/p\u003e","brand":"Precision Vision","offers":[{"title":"CATS®-D Disposable","offer_id":45921514193057,"sku":"10512","price":165.0,"currency_code":"USD","in_stock":true},{"title":"CATS®-R Prism","offer_id":45921514225825,"sku":"10511","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/4321\/7569\/files\/CATS_2.png?v=1776157247","url":"https:\/\/precision-vision.com\/products\/cats-tonometer-prism","provider":"Precision Vision","version":"1.0","type":"link"}