Tono-Pen AVIA® Tonometer Starter Kit by Reichert®

Tono-Pen AVIA® Tonometer, now with Quick-Tap® Measurement Mode… More confidence in fewer measurements. Tono-Pen AVIA® Tonometer is always ready-to-use and calibration-free. An award-winning ergonomic design, long life battery good for thousands of measurements, statistical confidence indicator, and now Quick-Tap Measurement Mode, make it the most advanced Tono-Pen® Tonometer yet!

$5,366.00

SKU: 230650 Categories: , Brand:

Description

Product Brochure, Instructions for Use, Quick Reference Guide. FAQs

Tono-Pen AVIA® Tonometer with Quick-Tap® Measurement Mode builds on all the features that made the classic Tono-Pen® XL Tonometer the most widely used handheld tonometer. Tono-Pen AVIA requires no calibration and is always ready-to-use, has an award-winning ergonomic design, longer battery life, and an enhanced IOP averaging technique with two measurement modes. This makes it the most advanced Tono-Pen yet!

Quick-Tap® Measurement Mode
Select from one of two measurement modes; the traditional First Generation Mode, which provides an IOP measurement typically in five taps, and now the Quick-Tap® Second Generation Measurement Mode where you can obtain a reliable IOP measurement in as few as two taps. This is especially useful for children and less cooperative patients.

Ergonomic Design and No Calibration Required!

With its award-winning, ergonomic design and soft-touch grips, the lightweight Tono-Pen AVIA Tonometer fits comfortably in any operator’s hand, ensuring consistent measurement technique among users. Routine calibration of Tono-Pen AVIA® Tonometer is not required. Spend less time worrying about your instruments and more time with your patients. To take a measurement, simply press the button once. When the light turns to green, Tono-Pen AVIA® Tonometer is ready to use. Gently tap the anesthetized cornea until a short beep sounds to alert the operator that the measurement is complete.

Gravity Independent

Unlike most other tonometers, Tono-Pen AVIA Tonometer can be used in any position, making it easy to measure all patients, including those who may be confined to a wheelchair or bed.

Large Dual-Sided Screens

The IOP measurement is displayed on two large, easy-to-read, LCD screens making it suitable for both left and right handed users.

Includes:

  • Tono-Pen AVIA®
  • Carrying case
  • 150 individually wrapped Ocu-Film + tip covers
  • Tono-Pen AVIA® Powercel Battery

Specifications:

Weight: 2.4oz. (71 g)
Length: 6.25 in. (16 cm)
Width: 0.75 in. (2 cm)
Thickness: 1.75 in. (4.4 cm)
Transducer: Micro Stain Gauge
Measurement Range: 5-55 mmHg
Power Source: Tono-Pen AVIA Powercel Battery Pack